Input
|
|
|
Input Voltage
|
|
90-264 VAC (120-370 VDC)
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Inrush Current
|
|
40 A max at 230 VAC, cold start 25ºC
|
|
|
|
Input Protection
|
|
Internally fused
|
|
|
|
AC Input Connector
|
|
AC mains lead, for UK or European mains lead contact technical sales.
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
12 to 28 VDC (for other output voltages 3.3 V to 48 V - please consult technical sales)
|
|
|
|
Initial Set Accuracy
|
|
±1.0%
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Start Up Delay
|
|
2 s max
|
|
|
|
Start Up Rise Time
|
|
50 ms
|
|
|
|
Hold Up Time
|
|
16/75 ms minimum at 115/230 VAC
|
|
|
|
Over/Undershoot
|
|
None at turn on/off
|
|
|
|
Transient Response
|
|
4% max. deviation, recovery to within 1% in 500 μs for a 25% load change
|
|
|
|
Ripple & Noise
|
|
1% pk-pk, 20MHz BW with 1µF capacitor connected across measurement points
|
|
|
|
Overvoltage Protection
|
|
115-135% Vnom, recycle input to reset
|
|
|
|
Overload Protection
|
|
110-150%, on primary power limit, auto recovery
|
|
|
|
Short Circuit Protection
|
|
Trip and restart (Hiccup mode)
|
|
|
|
Temperature Coefficient
|
|
0.05% /ºC
|
|
|
|
DC Output Connector
|
|
D-Sub Type. For customer specfic options please contact sales.
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
80-85%
|
|
|
|
Isolation
|
|
4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
|
|
|
|
Switching Frequency
|
|
70 kHz typical
|
|
|
|
MTBF
|
|
250 kHrs per MIL-HDBK-217F or Demonstrated
|
|
|
| |
|
|
|
|
|
Environmental
|
|
|
Operating Temperature
|
|
-40 ºC to +70 ºC, derate linearly from 100% load at +50 ºC to 50% load at +70 ºC. Start up at -30 ºC.
|
|
|
|
Cooling
|
|
Convection-cooled
|
|
|
|
Operating Humidity
|
|
95% RH, non-condensing
|
|
|
|
Shock
|
|
30 g pk, half sine, 6 axes
|
|
|
|
Vibration
|
|
2 g rms, 5 Hz to 500 kHz, 3 axis
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Emissions
|
|
MIL-STD-461E, CE102, RE102
|
|
|
|
EMI Immunity
|
|
MIL-STD 461E, CS101, 114, 115, 116 & RS103
|
|
|
|
Safety Approvals
|
|
Designed to meet EN60950, UL60950
|
|
|