Specifications
|
|
| |
|
|
Input
|
|
Input Voltage
|
|
90-264 VAC
|
|
Input Frequency
|
|
47-63 Hz
|
|
Input Current
|
|
1.6 A rms at 115 VAC, 0.8 A rms at 230 VAC
|
|
Inrush Current
|
|
60 A at 115 VAC, 120 A at 230 VAC, cold start +25 °C
|
|
Power Factor
|
|
0.98 typical
|
|
Earth Leakage Current
|
|
Class I versions: 90 µA max at 115 VAC/60 Hz, 150 µA at 230 VAC/50 Hz
|
|
Input Protection
|
|
Internal 3 A fuse in live and neutral lines
|
| |
|
|
|
Output
|
|
Output Voltage
|
|
12 to 48 VDC
|
|
Output Voltage Trim
|
|
Not user-adjustable
|
|
Initial Set Accuracy
|
|
±2%
|
|
Minimum Load
|
|
No minimum load required
|
|
Start Up Delay
|
|
2 s max at 115 VAC
|
|
Start Up Rise Time
|
|
<80 ms at 115 VAC
|
|
Hold Up Time
|
|
15 ms minimum at full load and 115 VAC
|
|
Line Regulation
|
|
0.5% maximum
|
|
Load Regulation
|
|
Total regulation <±5%
|
|
Transient Response
|
|
4% max deviation, recovery to within 1% in 500 µs for a 25% load change
|
|
Ripple & Noise
|
|
2% max pk-pk
|
|
Overvoltage Protection
|
|
110-140% Vnom, recycle input to reset
|
|
Overtemperature Protection
|
|
Unit shuts down, recycle input to reset
|
|
Overload Protection
|
|
110-150%, auto recovery
|
|
Short Circuit Protection
|
|
Trip and Restart (Hiccup mode)
|
|
Temperature Coefficient
|
|
0.04%/ºC
|
| |
|
|
|
General
|
|
Efficiency
|
|
85% typical, 82% for 12 and 15 V models
|
|
Isolation
|
|
4000 VAC Input to Output, 1500 VAC Input to Ground (Class I only), 500 VAC Output to Ground (class I only)
|
|
Switching Frequency
|
|
40-120 kHz variable
|
|
Power Density
|
|
3.7 W/cubic inch
|
|
MTBF
|
|
>175 kHrs per MIL-HDBK-217F
|
| |
|
|
|
Environmental
|
|
Operating Temperature
|
|
0 °C to +60 °C, derate from 100% power at +40 °C to 50% power at +60 °C
|
|
Cooling
|
|
Convection-cooled
|
|
Operating Humidity
|
|
10-95% RH, non-condensing
|
|
Storage Temperature
|
|
-20 °C to +80 °C
|
|
Operating Altitude
|
|
3000 m
|
|
Shock
|
|
30 g, 10 ms on 3 axis
|
|
Vibration
|
|
5-100 Hz, 2.31 m/s2, 20 mins 3 axis
|
| |
|
|
|
EMC and Safety
|
|
Emissions
|
|
EN55011/FCC/VCCI, class B conducted and radiated
|
|
Harmonic Currents
|
|
EN61000-3-2
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
ESD Immunity
|
|
EN61000-4-2, level 3 Perf Criteria A
|
|
Radiated Immunity
|
|
EN61000-4-3, level 2 Perf Criteria A
|
|
EFT/Burst
|
|
EN61000-4-4, level 3 Perf Criteria A
|
|
Surge
|
|
EN61000-4-5, level 3 Perf Criteria A
|
|
Conducted Immunity
|
|
EN61000-4-6, 3 V Perf Criteria A
|
|
Magnetic Field
|
|
EN61000-4-8, 3 A/m Perf Criteria A
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, >95% 5000 ms Perf Criteria A, B, B
|
|
Safety Approvals
|
|
EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, CE Mark
|