Input
|
|
|
Input Voltage Range
|
|
12 V (10-17 VDC), 24 V (20-30 VDC)
|
|
|
|
Input Current
|
|
See datasheet
|
|
|
|
Inrush Current
|
|
25 A max at 30 V
|
|
|
|
Input Filter
|
|
Pi network
|
|
|
|
Patient Leakage Current
|
|
2 μA max
|
|
|
|
Undervoltage Lockout
|
|
12 V model, on at <9 V, off >8.5 V, 24 V model on at <18.8 V, off >16 V
|
|
|
|
Input Surge
|
|
12 V models 25 V for 3 s, 24 V model 50 V for 3 s
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Output Voltage Trim
|
|
±10%
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Initial Set Accuracy
|
|
±1% max
|
|
|
|
Start Up Delay
|
|
5 ms typical
|
|
|
|
Start Up Rise Time
|
|
2 ms typical
|
|
|
|
Line Regulation
|
|
±0.3% max
|
|
|
|
Load Regulation
|
|
±2% max 0% to 10% load, ±1% max 10% to 100% load
|
|
|
|
Cross Regulation
|
|
±4% max on dual with one o/p set to 50% load and the other varied from 0% to 100% load
|
|
|
|
Transient Response
|
|
4% max deviation, recovery to within 1% in <500 μs for a 50% load change at 0.25 A/μs rate
|
|
|
|
Ripple & Noise
|
|
1% pk-pk max at 20 mHz BW
|
|
|
|
Overload Protection
|
|
120% - 200%
|
|
|
|
Overvoltage Protection
|
|
120% - 140%
|
|
|
|
Temperature Coefficient
|
|
±0.03/°C max
|
|
|
|
Short Circuit Protection
|
|
Trip and Restart (hiccup mode), Auto Recovery
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
See datasheet
|
|
|
|
Isolation
|
|
5000 VAC for 10 ms, 1600 VAC basic isolation for 1 min.
|
|
|
|
Input to Output Capacitance
|
|
20 pF max
|
|
|
|
Switching Frequency
|
|
JHM03: 180 kHz to 1.2 MHz variable, JHM06: 200 kHz to 1.6 MHz variable
|
|
|
|
MTBF
|
|
>1 MHrs typical to MIL-STD-217F
|
|
|
| |
|
|
|
|
|
Environmental
|
|
|
Operating Temperature
|
|
-20 ºC to +100 ºC, derate from 100% load at +60 ºC to no load at 100 ºC
|
|
|
|
Case Temperature
|
|
+100 ºC max
|
|
|
|
Storage Temperature
|
|
-40 ºC to +100 ºC
|
|
|
|
Operating Humidity
|
|
5-90%, non-condensing
|
|
|
|
Cooling
|
|
Natural convection
|
|
|