Specifications
|
|
| |
|
|
|
|
|
Input Voltage
|
|
90-264 VAC
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Input Current
|
|
0.4 A max AEL15-20, 1.0 A max AEL40, 1.6 A max AEL60, 1.1 A max AEL80
|
|
|
|
Inrush Current
|
|
15/30 A for 115/230 VAC, cold start
|
|
|
|
Earth Leakage Current
|
|
0.75 mA at 240 VAC
|
|
|
|
Power Factor
|
|
Meets EN61000-3-2, Class A
|
|
|
|
Input Protection
|
|
Fitted with internal fuse, AEL15/20: T1 A, 250 V, AEL40: T2 A, 250 V, AEL60/80: T3.15 A, 250 V
|
|
|
|
No Load Input Power
|
|
<0.5 W
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Hold Up Time
|
|
AEL15: 5 ms min, AEL20/40: 12 ms min, AEL60/80: 16 ms min, at full load 110 VAC
|
|
|
|
Start Up Delay
|
|
AEL20/40: 0.5 s, AEL15/60/80: 2.0 s max at full load 100 VAC
|
|
|
|
Transient Response
|
|
2% deviation, recovery to within 1% of nominal in 500 µs for 50% load change
|
|
|
|
Line Regulation
|
|
See datasheet
|
|
|
|
Load Regulation
|
|
See datasheet
|
|
|
|
Ripple & Noise
|
|
1% pk+pk max, 20 MHz bandwidth
|
|
|
|
Overvoltage Protection
|
|
112-132% (AEL40/60/80 only)
|
|
|
|
Overload Protection
|
|
110-150% (AEL20/40/60/80 only)
|
|
|
|
Short Circuit Protection
|
|
Trip & restart (hiccup mode), auto recovery
|
|
|
|
Temperature Coefficient
|
|
±0.04%/°C
|
|
|
| |
|
|
|
|
|
|
|
|
Efficiency
|
|
85% typical, Energy Star Level V compliant, not AEL40
|
|
|
|
Isolation
|
|
3000 VAC Input to Output, 1500 VAC Input to Ground (not C8 version), 500 VDC Output to Ground (not C8 version)
|
|
|
|
Switching Frequency
|
|
63 kHz typical
|
|
|
|
MTBF
|
|
>100 kHrs to MIL-HDBK-217F at 25 ºC, GB
|
|
|
| |
|
|
|
|
|
|
|
|
Operating Temperature
|
|
0 °C to +70 °C, derate from 100% power at +40 °C to 50% power at +70 °C
|
|
|
|
Storage Temperature
|
|
-40 °C to +85 °C
|
|
|
|
Cooling
|
|
Convection cooled
|
|
|
|
Relative Humidity
|
|
5-95% RH, non-condensing
|
|
|
|
Operating Altitude
|
|
3000 m
|
|
|
|
Shock
|
|
10 g, 10 ms on 3 axes
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Emissions
|
|
EN55022 FCC Paart-15C Level B conducted & radiated
|
|
|
|
Harmonic Current
|
|
EN61000-3-2 Class A
|
|
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
|
|
ESD Immunity
|
|
EN61000-4-2 Level 3 Perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3 3 V/m Perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4 Level 2 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5 Level 3 Perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6 Level 2 Perf Criteria A
|
|
|
|
Magnetic Field
|
|
EN61000-4-8 1 A/m Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B
|
|
|
|
Safety
|
|
EN60950-1: UL/cUL60950-1, Approved as Limited Power Source (AEL15-60 only), China Compulsory Certification (CCC) qualified.
|
|
|