Specifications
|
|
| |
|
|
Input
|
|
|
Input Voltage
|
|
90-264 VAC
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Input Current
|
|
AEB36: 1.00 A max AEB45: 1.20 A max AEB70: 1.50 A max AEB100: 1.85 A max
|
|
|
|
Inrush Current
|
|
AEB36: 60 A max at 240 VAC AEB45: 70 A max at 240 VAC AEB70: 80 A max at 240 VAC AEB100: 120 A max at 240 VAC
|
|
|
|
Earth Leakage Current
|
|
<3.5 mA (AEB45/70/100)
|
|
|
|
Power Factor
|
|
Meets EN61000-3-2, class A
|
|
|
|
Input Protection
|
|
Fitted with an internal fuse: AEB36 T1A/250 VAC, AEB45/70/100 T2A/250 VAC
|
|
|
|
No Load Input Power
|
|
<0.5 W
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Initial Set Accuracy
|
|
±2%, set at 60% load
|
|
|
|
Minimum Load
|
|
No minimum load requirement
|
|
|
|
Hold Up Time
|
|
AEB36/45/70: 8 ms at 115 VAC, AEB100: 20 ms at 115 VAC
|
|
|
|
Line Regulation
|
|
±1%
|
|
|
|
Load Regulation
|
|
See datasheet
|
|
|
|
Ripple & Noise
|
|
1% pk-pk max, 20 MHz bandwidth (see datasheet)
|
|
|
|
Overvoltage Protection
|
|
Typical 125% max, recycle input to restart
|
|
|
|
Overload Protection
|
|
Trip & restart mode (hiccup mode)
|
|
|
|
Short Circuit Protection
|
|
Continuous
|
|
|
|
Temperature Coefficient
|
|
±0.04%/ ˚C
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
85% minimum at 230 VAC & 100% load
|
|
|
|
Isolation
|
|
AEB36: 3000 VAC Input to Output, AEB45/70/100: 3000 VAC Input to Output, 1500 VAC Input to Ground. Negative output is connected to ground. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number
|
|
|
|
Switching Frequency
|
|
AEB36/70: 60 kHz typical, AEB45: 100 kHz ± typical, AEB100: 80 kHz typical PFC converter, 130 kHz typical main converter
|
|
|
|
MTBF
|
|
AEB36: >360 kHrs, AEB45: >300 kHrs, AEB70: >200 kHrs, AEB100: >150 kHrs to MIL-HDBK-217F at 25°C, GB
|
|
|
| |
|
|
|
|
|
Environmental
|
|
|
Operating Temperature
|
|
AEB36/45/70: 0 °C to +60 °C derate linearly from 100% load at +40 °C to 60% load at +60 °C, AEB100: 0 °C to +60 °C derate linearly from 100% load at +40 °C to 50% load at +60 °C
|
|
|
|
Storage Temperature
|
|
-20 ˚C to +85 ˚C
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Emissions
|
|
EN55022, Level B conducted & radiated
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2 Class A
|
|
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
|
|
ESD Immunity
|
|
EN61000-4-2 Level 2 (contact) Perf Criteria A, EN61000-4-2 Level 3 (air) Perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3, 3 V/m Perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4, level 2 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5, installation class 3, Perf Criteria B
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, Level 2 Perf Criteria A
|
|
|
|
Magnetic Field
|
|
EN61000-4-8, 3 A/m Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B
|
|
|
|
Safety Approvals
|
|
EN60950-1: UL/cUL60950-1, China Compulsory Certification (CCC) qualified (AEB36/70 only)
|
|
|