Specifications
|
|
| |
|
|
Input
|
|
|
Input Voltage
|
|
90-264 VAC
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Input Current
|
|
100 W: 1.2 A at 115 VAC, 0.55 A at 230 VAC, 120 W: 1.4 A at 115 VAC, 0.63 A at 230 VAC, 150 W: 2.0 A at 115 VAC, 0.80 A at 230 VAC
|
|
|
|
Power Factor
|
|
0.95 typical
|
|
|
|
Earth Leakage Current
|
|
200 µA max at 115 VAC, 400 µA max at 230 VAC (except C2 version)
|
|
|
|
No Load Input Power
|
|
<0.5 W
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage Trim
|
|
See table on datasheet
|
|
|
|
Output Voltage Trim
|
|
Not user-adjustable
|
|
|
|
Initial Set Accuracy
|
|
See note 3 on datasheet
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Start Up Delay
|
|
2 s max at 100 VAC
|
|
|
|
Start Up Rise Time
|
|
25 ms max
|
|
|
|
Hold Up Time
|
|
100 W & 120 W: 16 ms minimum at 90 VAC 150 W: 9 ms minimum at 90 VAC
|
|
|
|
Line Regulation
|
|
±0.5% maximum
|
|
|
|
Load Regulation
|
|
See table on datasheet
|
|
|
|
Transient Response
|
|
5% max. deviation, recovery to within 1% in 10 ms for a 50% load change
|
|
|
|
Ripple & Noise
|
|
1.5% max pk-pk (see note 1 on datasheet)
|
|
|
|
Overvoltage Protection
|
|
110-140% Vnom, recycle input to reset
|
|
|
|
Overtemperature Protection
|
|
Unit shuts down, recycle input to reset
|
|
|
|
Overload Protection
|
|
125% typical, auto recovery
|
|
|
|
Short Circuit Protection
|
|
Trip and restart (Hiccup mode)
|
|
|
|
Temperature Coefficient
|
|
0.04%/°C
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
See table on datasheet
|
|
|
|
Isolation
|
|
3000 VAC Input to Output 1500 VAC Input to Ground (not C2 version) Output 0 V and connector shell are electrically connected to Input Ground (not C2 version)
|
|
|
|
Switching Frequency
|
|
PFC 30-90 kHz variable PWM 100-120 kHz typical
|
|
|
|
Power Density
|
|
5.95 W/In3 for 150 W
|
|
|
|
MTBF
|
|
>150 kHrs to MIL-HDBK-217F at 25 ºC, GB
|
|
|
| |
|
|
|
|
|
|
|
|
Operating Temperature
|
|
0 °C to +50 °C, derate from 100% power at +40 °C to 75% power at +50 °C
|
|
|
|
Operating Humidity
|
|
10-95% RH, non-condensing
|
|
|
|
Storage Temperature
|
|
-20 °C to +80 °C
|
|
|
|
Operating Altitude
|
|
3000 m
|
|
|
|
Shock
|
|
30 g, 10 ms on 3 axes
|
|
|
|
Vibration
|
|
5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
|
|
|
| |
|
|
|
|
|
|
|
|
Emissions
|
|
EN55022, Class B conducted and radiated
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2, Class A
|
|
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
|
|
ESD Immunity
|
|
EN61000-4-2, 8 kV air, 4 kV contact, Perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3, level 2 Perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4, level 2 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5, level 2 Perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, level 2 Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B
|
|
|
|
Safety Approvals
|
|
EN60950-1, cUL60950-1
|
|
|