Specifications
|
|
| |
|
|
Input
|
|
|
Input Voltage
|
|
90-264VAC
|
|
|
|
Input Frequency
|
|
47-63Hz
|
|
|
|
Input Current
|
|
1.6 A rms at 115VAC, 0.8 A rms at 230VAC
|
|
|
|
Inrush Current
|
|
60 A at 115 VAC, 120 A at 230 VAC cold start +25 °C
|
|
|
|
Power Factor
|
|
0.98 typical at 115 VAC
|
|
|
|
Earth Leakage Current
|
|
150 μA max at 115 VAC/60 Hz, 250 μA max at 230 VAC/50 Hz
|
|
|
|
Input Protection
|
|
Internal 3 A fuse
|
|
|
|
Standby Power Consumption
|
|
<0.75 W
|
|
|
| |
|
|
|
|
|
|
|
|
Output Voltage
|
|
12 to 48 VDC
|
|
|
|
Output Voltage Adjustment
|
|
Not user-adjustable
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Start Up Delay
|
|
2 s max at 115 VAC
|
|
|
|
Start Up Rise Time
|
|
<80 ms at 115 VAC
|
|
|
|
Hold Up Time
|
|
15 ms min at full load and 115 VAC
|
|
|
|
Initial Set Accuracy
|
|
±2%
|
|
|
|
Line Regulation
|
|
±0.5% max
|
|
|
|
Load Regulation
|
|
See datasheet
|
|
|
|
Transient Response
|
|
4% max deviation, recovery to within 1% in 500 μs for a 25% load change
|
|
|
|
Ripple and Noise
|
|
2% max pk-pk
|
|
|
|
Overvoltage Protection
|
|
110-140% Vnom, recycle input to reset
|
|
|
|
Overload Protection
|
|
110-150%, auto-recovery
|
|
|
|
Overtemperature Protection
|
|
Unit shuts down, recycle input to reset
|
|
|
|
Short Circuit protection
|
|
Trip and Restart (Hiccup mode)
|
|
|
|
Temperature Coefficient
|
|
0.04%/°C
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
86% typical (80% min for 12 & 15 V models)
|
|
|
|
Isolation
|
|
3000 VAC Input to Output, 1500 VAC Input to Ground, Output 0 V is electrically connected to Input Ground
|
|
|
|
Switching Frequency
|
|
20-100 kHz variable
|
|
|
|
Power Density
|
|
4.9 Watts per cubic inch
|
|
|
|
MTBF
|
|
>100 kHrs per MIL-HDBK-217F
|
|
|
| |
|
|
|
|
|
Environmental
|
|
|
Operating Temperature
|
|
0 °C to +70 °C derate from 100% power at +50 °C to 60% power at +70 °C
|
|
|
|
Storage Temperature
|
|
-20 °C to +80 °C
|
|
|
|
Cooling
|
|
Convection-cooled
|
|
|
|
Operating Humidity
|
|
10-90% RH non-condensing
|
|
|
|
Operating Altitude
|
|
3000 m
|
|
|
|
Shock
|
|
30 g, 10 ms on 3 axis
|
|
|
|
Vibration
|
|
5-100Hz 2.31 m/s2 20 mins 3 axis
|
|
|
| |
|
|
|
|
|
|
|
|
Emissions
|
|
EN55022/FCC/VCCI Class B conducted and radiated
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2
|
|
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
|
|
ESD Immunity
|
|
EN61000-4-2, level 3 Perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3, level 3 Perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, 10 V Perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4, level 2 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5, level 3 Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B
|
|
|
|
Safety Approvals
|
|