Specifications
|
|
|
| |
|
|
|
Input
|
|
|
Input Voltage
|
|
90-264 VAC
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Input Current
|
|
1.5/0.7 A for AEH45, 1.9/1.5 A for AEH80, 3.2/1.7 A for AEH130 at 115/230 VAC
|
|
|
|
Inrush Current
|
|
AEH45 & AEH80: 30 A max at 230 VAC, AEH130: 60 A max at 230 VAC cold start
|
|
|
|
Power Factor
|
|
EN61000-3-2 class A
|
|
|
|
Earth Leakage Current
|
|
<0.5 mA at 115 VAC/60 Hz, <0.75 mA at 230 VAC/50 Hz
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Start Up Delay
|
|
2 s max
|
|
|
|
Hold Up Time
|
|
16 ms min (>50 ms AEH130)
|
|
|
|
Initial Set Accuracy
|
|
5%
|
|
|
|
Line Regulation
|
|
See datasheet
|
|
|
|
Load Regulation
|
|
See datasheet
|
|
|
|
Transient Response
|
|
4% max deviation recovering to within 1% in 5 ms for a 50% load change
|
|
|
|
Ripple and Noise
|
|
2% max pk-pk for outputs ≤3.3 V, 1% pk-pk for all other outputs, 20 MHz BW
|
|
|
|
Overvoltage Protection
|
|
112-132% Vnom, auto reset
|
|
|
|
Overload Protection
|
|
Output 1 only 110-150% of nominal
|
|
|
|
Temperature Coefficient
|
|
±0.04%/°C max
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
Up to 80%
|
|
|
|
Isolation
|
|
3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
|
|
|
|
Switching Frequency
|
|
67-83 kHz for AEH45, 58 kHz typical for AEH80, 53-76 kHz for AEH130
|
|
|
|
MTBF
|
|
100 kHrs MIL-HDBK-217F
|
|
|
| |
|
|
|
|
|
Environmental
|
|
|
Operating Temperature
|
|
0 °C to +70 °C, derate linearly from 100% load at +40 °C to 50% load at +70 °C
|
|
|
|
Storage Temperature
|
|
-40 °C to +85 °C
|
|
|
|
Operating Humidity
|
|
5-95% RH, non-condensing
|
|
|
|
Vibration
|
|
2 g on 3 axis
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Emissions
|
|
EN55022 level B conducted & radiated
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2 Class A
|
|
|
|
Voltage Flicker
|
|
EN61000-3-2
|
|
|
|
ESD Immunity
|
|
EN61000-4-2 Level 2 Perf Criteria a
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3 Level 3 Perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6 Level 2 Perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4 Level 2 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5 Level 3 Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B
|
|
|
|
Safety Approvals
|
|
EN60950-1, UL60950-1, CSA C22.2 No. 950 per cUL, CE Mark
|
|
|