Specifications
|
|
| |
|
|
|
|
|
Input Voltage
|
|
85-264 VAC
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Input Current
|
|
0.85 A max at 115 VAC
|
|
|
|
Inrush Current
|
|
65 A max at 230 VAC
|
|
|
|
Power Factor
|
|
Conforms to EN61000-3-2, Class A
|
|
|
|
No Load Input Power
|
|
<0.3 W
|
|
|
|
Earth Leakage Current
|
|
<250 µA at 264 VAC, 60 Hz
|
|
|
|
Input Protection
|
|
Internal T2 A/250 V fuse in both line and neutral
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage Trim
|
|
See datasheet
|
|
|
|
Initial Set Accuracy
|
|
Single output: ±1% at 60% load, Multiple output: ±1% on V1, ±5% on V2, V3 at 60% load
|
|
|
|
Minimum Load
|
|
10% minimum load required on V1 & V2 of multi output versions
|
|
|
|
Start Up Delay
|
|
1.3 s max
|
|
|
|
Start Up Rise Time
|
|
15 ms typical
|
|
|
|
Hold Up Time
|
|
10 ms min at full load at 115 VAC
|
|
|
|
Line Regulation
|
|
±0.5% max
|
|
|
|
Load Regulation
|
|
V1 & V3: ±2%, V2: ±4%, see note 3 on datasheet
|
|
|
|
Cross Regulation
|
|
V2: 5%, 10-100% load change on V1
|
|
|
|
Transient Response
|
|
4% max deviation, recovering to less than 1% within 500 µs for 50% step load change at 1 A/µs
|
|
|
|
Ripple & Noise
|
|
1% pk-pk, measured with 20 MHz bandwidth
|
|
|
|
Overvoltage Protection
|
|
110-140% of nominal output voltage on V1 only, recycle input to reset
|
|
|
|
Overload Protection
|
|
Single output: 140-160% of nominal power Multiple output: 120-150% of nominal power on V1 and V2 only
|
|
|
|
Short Circuit Protection
|
|
Trip and restart (Hiccup mode)
|
|
|
|
Temperature Coefficient
|
|
±0.02%/°C max
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
See datasheet
|
|
|
|
Isolation
|
|
4000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground
|
|
|
|
Switching Frequency
|
|
40-130 kHz variable
|
|
|
|
MTBF
|
|
>400 kHrs to MIL-HDBK-217F at 25 ºC, GB
|
|
|
| |
|
|
|
|
|
|
|
|
Operating Temperature
|
|
-10 °C to +70 °C, derate from 100% load at 50 °C to 50% load at 70 °C
|
|
|
|
Cooling
|
|
Natural convection
|
|
|
|
Operating Humidity
|
|
5% to 95% RH, non condensing
|
|
|
|
Storage Temperature
|
|
-40 °C to +85 °C
|
|
|
|
Shock
|
|
30 g pk, half sine, 6 axes
|
|
|
|
Vibration
|
|
2 g rms, 5 Hz to 500 kHz, 3 axes
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Emissions
|
|
EN55022, level B conducted & radiated
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2, class A
|
|
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
|
|
ESD Immunity
|
|
EN61000-4-2, ±4 kV indirect contact, Perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3, 3 V/m, Perf Criteria A
|
|
|
|
EFT / Burst
|
|
EN61000-4-4, level 2 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5, level 2 Perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, 3 V Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B
|
|
|
|
Safety Approvals
|
|
EN60950-1, cUL60950, IEC60950-1, EN60601-1, cUL60601-1, IEC60601-1
|
|
|
|
|
|
|
|
|
|
|
Model Number
|
Input
|
Output
|
Power
|
|
|
|
|
|
|
|
|
|
|
ECP40UD01
|
85-264 V
|
5 V/5 A, 12 V/2 A
|
40 W
|
|
|
|
ECP40UD02
|
85-264 V
|
5 V/5 A, 15 V/1.5 A
|
40 W
|
|
|
|
ECP40UD03
|
85-264 V
|
5 V/5 A, 24 V/1 A
|
40 W
|
|
|
|
ECP40US05
|
85-264 V
|
5 V/6 A
|
40 W
|
|
|
|
ECP40US12
|
85-264 V
|
12 V/3.34 A
|
40 W
|
|
|
|
ECP40US15
|
85-264 V
|
15 V/2.67 A
|
40 W
|
|
|
|
ECP40US18
|
85-264 V
|
18 V/2.22 A
|
40 W
|
|
|
|
ECP40US24
|
85-264 V
|
24 V/ 1.67 A
|
40 W
|
|
|
|
ECP40US30
|
85-264 V
|
30 V/1.34 A
|
40 W
|
|
|
|
ECP40US48
|
85-264 V
|
48 V/0.84 A
|
40 W
|
|
|
|
ECP40UT01
|
85-264 V
|
5 V/5 V, 12 V/2 A, -12 V/0.5 A
|
40 W
|
|
|
|
ECP40UT02
|
85-264 V
|
5 V/5 V, 15 V/1.5 A, -15 V/0.5 A
|
40 W
|
|
|
|
ECP40UT03
|
85-264 V
|
5 V/5 V, 24 V/1.0 A, +12 V/0.5 A
|
40 W
|
|
|
|
ECP40UT04
|
85-264 V
|
5 V/5 V, 24 V/1 A, -12 V/0.5 A
|
40 W
|
|
|