Specifications
|
|
|
|
|
|
Input Voltage
|
|
80-264 VAC (120-370 VDC), see derating curve on datasheet
|
|
Input Frequency
|
|
47-400 Hz, see note 1 on datasheet
|
|
Input Current
|
|
0.75 A typical at 115 VAC, full load 0.45 A typical at 230 VAC, full load
|
|
Inrush Current
|
|
40 A max at 230 VAC, cold start 25 ºC
|
|
Power Factor
|
|
EN61000-3-2, class A
|
|
No Load Input Power
|
|
US05, 12 & 24 models <0.3 W, US48 <0.5 W
|
|
Earth Leakage Current
|
|
260 μA at 264 VAC/60 Hz max, 80/160 μA typical 115/230 VAC
|
|
Input Protection
|
|
T3.15 A/250 V internal fuse in line and neutral
|
|
|
|
|
Output Voltage
|
|
05-48 VDC (see tables)
|
|
Output Voltage Trim
|
|
±10%
|
|
Initial Set Accuracy
|
|
±1%
|
|
Minimum Load
|
|
No miniumum load required
|
|
Start Up Delay
|
|
1 s typical
|
|
Start Up Rise Time
|
|
50 ms
|
|
Hold Up Time
|
|
16 ms min at 115 VAC
|
|
Drift
|
|
±0.2% after 20 min warm up
|
|
Line Regulation
|
|
±0.5% max
|
|
Load Regulation
|
|
±1%
|
|
Over/Undershoot
|
|
5% typical
|
|
Transient Response
|
|
4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change
|
|
Ripple & Noise
|
|
1% pk-pk V1, 20 MHz bandwidth
|
|
Overvoltage Protection
|
|
115-140% Vnom, recycle input to reset
|
|
Overload Protection
|
|
110-200%
|
|
Short Circuit Protection
|
|
Continuous trip and restart (Hiccup mode)
|
|
Temperature Coefficient
|
|
0.05%/˚C
|
|
|
|
|
Efficiency
|
|
87% typical
|
|
Isolation Capacitance
|
|
4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground
|
|
Switching Frequency
|
|
65 KHz typical
|
|
Power Density
|
|
7.9 W/in3
|
|
MTBF
|
|
1072 kHrs to MIL-HDBK-217F at 25 °C, GB
|
|
|
|
|
Operating Temperature
|
|
-20 °C to +70 °C derate linearly from +50 °C at 2.5%/°C to 50% load at +70 °C.
|
|
Cooling
|
|
Convection
|
|
Operating Humidity
|
|
95% RH, non-condensing
|
|
Storage Temperature
|
|
-40 ˚C to +85 ˚C
|
|
Operating Altitude
|
|
3000 m
|
|
Shock
|
|
30 g pk, half sine, 6 axes
|
|
Vibration
|
|
2 g rms, 5 Hz to 500 kHz, 3 axes
|
|
|
|
|
Low Voltage PSU EMC
|
|
EN61204-3, high severity level as below
|
|
Emissions
|
|
EN55022 level B conducted EN55022 level A radiated ECS45, Level B ECS25
|
|
Harmonic Currents
|
|
EN61000-3-2, class A
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
Radiated Immunity
|
|
EN61000-4-3, level 3 Perf Criteria A
|
|
EFT/Burst
|
|
EN61000-4-4, level 3 Perf Criteria A
|
|
Surge
|
|
EN61000-4-5, installation class 3 Perf Criteria A
|
|
Conducted Immunity
|
|
EN61000-4-6, level 3 Perf Criteria A
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation.
|
|
Safety Approvals
|
|
EC60950-1 CB report, UL60950-1, TUV EN60950-1 IEC60601-1 CB report, UL60601-1, TUV 60601-1
|
|
Equipment Protection Class
|
|
Class I and Class II
|