Specifications
|
|
| |
|
|
Input
|
|
|
Input Voltage Range
|
|
10.0-40.0 VDC
|
|
|
|
Transient Input Range
|
|
50 VDC for 100 ms
|
|
|
|
Inrush Current
|
|
<40 A at 28 VDC
|
|
|
|
Turn On
|
|
>8.7 VDC
|
|
|
|
Turn Off
|
|
<8.0 VDC
|
|
|
|
Input Reverse Voltage Protection
|
|
None
|
|
|
|
Input Current
|
|
See table on datasheet
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
See table on datasheet
|
|
|
|
Output Voltage Trim
|
|
-20%, +10% (±10% for 3.3 V version), see note 4 of datasheet
|
|
|
|
Minimum Load
|
|
No minimum load required on single output models, 5% load required on each output of dual output models
|
|
|
|
Line Regulation
|
|
±1% Vout nominal
|
|
|
|
Load Regulation
|
|
Single Output: ±1% Vout nominal, Dual Output: ±2%
|
|
|
|
Output Set Tolerance
|
|
±1.5% max
|
|
|
|
Ripple & Noise
|
|
≤5 Vout: 50 mV pk-pk max, >5 Vout: 100 mV pk-pk, at max load and 20 MHz bandwidth
|
|
|
|
Overvoltage Protection
|
|
120-140% Vout max
|
|
|
|
Overcurrent Protection
|
|
110-140% at nominal input voltage
|
|
|
|
Short Circuit Protection
|
|
Output turns off until the short is removed
|
|
|
|
Thermal Warning
|
|
Active when internal temp is >105 ºC
|
|
|
|
Remote Sense
|
|
10 %, see note 4 of datasheet
|
|
|
|
Cross Regulation
|
|
±4% on dual outputs, see note 2 of datasheet
|
|
|
|
Transient Response
|
|
±4% max deviation recovery to within 1% in 500 µs for a 50% load change at 0.1 A/µs
|
|
|
|
Start Up Time
|
|
<100 ms
|
|
|
|
Start Up Rise Time
|
|
<20 ms
|
|
|
|
Current Share
|
|
Parallel up to 4 modules, single output versions only
|
|
|
|
Temperature Coefficient
|
|
0.03%/ºC
|
|
|
|
Remote On/Off
|
|
On = >3.5 V or open circuit, Off = <1.8 V
|
|
|
|
Maximum Capacitive Load
|
|
300 µF x Iout max for startup within 100 ms
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
See table on datasheet
|
|
|
|
Isolation
|
|
1500 VDC Input to Output 1000 VDC Input to Case 1000 VDC Output to Case
|
|
|
|
Isolation Capacitance
|
|
2500 pF
|
|
|
|
Switching Frequency
|
|
Fixed, 450 kHz typical
|
|
|
|
Frequency Synchronization
|
|
450-550 kHz
|
|
|
|
MTBF
|
|
>1 MHrs to MIL-HDBK-217F at 25 °C, GF
|
|
|
| |
|
|
|
|
|
Environmental
|
|
|
Case Temperature
|
|
-40 °C to +100 °C (start up at -55 °C)
|
|
|
|
Operating Humidity
|
|
95% Relative Humidity 240h MIL-STD-810F Method 507.4
|
|
|
|
Storage Temperature
|
|
-60 °C to +125 °C
|
|
|
|
Operating Altitude
|
|
Tested to 70000 ft (21336 m)
|
|
|
|
Shock
|
|
75 g MIL-STD-810F Method 516.5
|
|
|
|
Vibration
|
|
15 to 2000 Hz MIL-STD-810F Method 514.5, table 514.5-VIII
|
|
|
|
Bump
|
|
2000 Bumps in each axis 40 g MIL-STD-810F Method 516.5
|
|
|
|
Salt Atmosphere
|
|
48 hours MIL-STD-810F Method 509.4
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Conducted Emissions
|
|
EN55022 Conducted Level B* MIL-STD 461F: CE102* (see datasheet)
|
|
|
|
Immunity
|
|
MIL-STD-704 B-F, MIL-STD-1275A/B/C/D* (see datasheet)
|
|
|
|
Conducted Susceptibilty
|
|