Specifications
|
|
|
|
|
|
|
|
Input
|
|
|
Input Voltage
|
|
80-275 VAC (See derating curve on datasheet)
|
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
|
Input Current
|
|
2.4 A typical at 115 VAC, full load, 1.2 A typical at 230 VAC, full load
|
|
|
|
|
Power Factor
|
|
EN61000-3-2, class A
|
|
|
|
|
Earth Leakage Current
|
|
250 µA at 264 VAC/60 Hz max.
|
|
|
|
|
Input Protection
|
|
Internal T5.0 A/250 V fuse in line and neutral
|
|
|
|
|
|
|
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
12-48 VDC (see tables on datasheet)
|
|
|
|
|
Output Voltage Trim
|
|
±3% (see mechanical details on datasheet)
|
|
|
|
|
Initial Set Accuracy
|
|
±0.5% V1, ±5% V2
|
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
|
Start Up Delay
|
|
1 s typical
|
|
|
|
|
Start Up Rise Time
|
|
50 ms typical
|
|
|
|
|
Hold Up Time
|
|
16 ms min at 115 VAC
|
|
|
|
|
Drift
|
|
±0.2% after 20 min warm up
|
|
|
|
|
Line Regulation
|
|
±0.5% max
|
|
|
|
|
Load Regulation
|
|
±1% V1, ±5% V2
|
|
|
|
|
Over/Undershoot
|
|
5% typical
|
|
|
|
|
Transient Response
|
|
4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change
|
|
|
|
|
Ripple & Noise
|
|
1% pk-pk, 20 MHz bandwidth
|
|
|
|
|
Overvoltage Protection
|
|
115-140% Vnom, recycle input to reset (V1 only)
|
|
|
|
|
Overload Protection
|
|
125-165% Inom V1 only
|
|
|
|
|
Short Circuit Protection
|
|
Continuous trip and restart (Hiccup mode)
|
|
|
|
|
Temperature Coefficient
|
|
0.05%/ ˚C
|
|
|
|
|
Remote On/Off (Inhibit / Enable)
|
|
Uncommitted isolated optocoupler diode, powered diode inhibits V1(Inhibit/Enable)
|
|
|
|
|
|
|
|
|
|
|
|
General
|
|
|
Efficiency
|
|
Up to 95%
|
|
|
|
|
Isolation
|
|
4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
|
|
|
|
|
Switching Frequency
|
|
PFC 30-500 kHz, Boost 25.6 kHz, Main 51.2 kHz
|
|
|
|
|
Signals
|
|
Power Fail, Remote On/Off, 5 V Standby
|
|
|
|
|
MTBF
|
|
365 kHrs per MIL-HDBK-217F 25ºC, GB
|
|
|
|
|
|
|
|
|
|
|
|
Environmental
|
|
|
Operating Temperature
|
|
-10 ˚C to +70 ˚C derate linearly from +50 ˚C at 2.5%/˚C to 50% load at +70 ˚C. (See derating curve on datasheet)
|
|
|
|
|
Cooling
|
|
Convection cooled
|
|
|
|
|
Operating Humidity
|
|
95% RH, non-condensing
|
|
|
|
|
Storage Temperature
|
|
-40 ˚C to +85 ˚C
|
|
|
|
|
Operating Altitude
|
|
3000 m
|
|
|
|
|
Shock
|
|
30 g pk, half sine, 6 axes
|
|
|
|
|
Vibration
|
|
2 g rms, 5 Hz to 500 kHz, 3 axes
|
|
|
|
|
|
|
|
|
|
|
|
EMC and Safety
|
|
|
Low Voltage PSU EMC
|
|
EN61204-3, high severity level (see datasheet)
|
|
|
|
|
Emissions
|
|
EN5022 level B conducted, EN55022 level B radiated
|
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2, class A
|
|
|
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3, level 3 Perf Criteria A
|
|
|
|
|
EFT/Burst
|
|
EN61000-4-4, level 3 Perf Criteria A
|
|
|
|
|
Surge
|
|
EN61000-4-5, installation class 3, Perf Criteria A
|
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, level 3 Perf Criteria A
|
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation.
|
|
|
|
|
Safety Approvals
|
|
See Safety Approvals (see datasheet)
|
|
|
|
|
Equipment Protection Class
|
|
Class I
|
|
|
|