Specifications
|
|
|
|
|
|
Input
|
|
|
Input Voltage Range
|
|
18.5-34 VDC steady state
|
|
|
|
|
Input Current
|
|
38 A at 18.5 V 400 W
|
|
|
|
|
Inrush Current
|
|
<60 A
|
|
|
|
|
Input Reverse Voltage Protection
|
|
Yes
|
|
|
|
|
Input Transient
|
|
MIL-STD-1275A/B/C/D
|
|
|
|
|
Undervoltage Lockout
|
|
Vin <18 VDC
|
|
|
|
|
|
|
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
O/P 1-4: regulated outputs 2-48 VDC
|
|
|
|
|
Output Voltage Adj
|
|
O/P 1-4: 10-110% factory set. For outputs below 90% of nominal, a minimum load of 10% is required
|
|
|
|
|
Aux. Output Voltage
|
|
Vout Aux (min) = Vin - 2 VDC
|
|
|
|
|
Aux. Output Power
|
|
100 W for MCC300, 200 W for MCC600 (9 A max)
|
|
|
|
|
Maximum Aux Output
|
|
Vout clamped <36 VDC
|
|
|
|
|
Minimum Load
|
|
No minimum load (output ripple increased at Pout <10% Pout max)
|
|
|
|
|
Line Regulation
|
|
1% max
|
|
|
|
|
Load Regulation
|
|
1% max
|
|
|
|
|
Cross Regulation
|
|
Outputs 1-4 individually regulated, no cross regulation
|
|
|
|
|
Output Set Tolerance
|
|
±100 mV
|
|
|
|
|
External Hold Up
|
|
External connection for additional hold up capacitance, consult sales
|
|
|
|
|
Ripple & Noise
|
|
50 mV or 1% pk-pk, whichever is the greater, 20 MHz bandwidth
|
|
|
|
|
Low Noise (Option ‘Q’)
|
|
Outputs 1 & 2: 25 mV reduction (MCC400 only) Outputs 3 & 4: 45 mV reduction (MCC400 only)
|
|
|
|
|
Temperature Coefficient
|
|
±0.05%/˚C
|
|
|
|
|
Overvoltage Protection
|
|
110-120% of nominal output
|
|
|
|
|
Overcurrent Protection
|
|
110-120% of nominal output
|
|
|
|
|
Short Circuit Protection
|
|
Constant current
|
|
|
|
|
Overtemperature Protection
|
|
>+90 ºC baseplate temperature, auto restart
|
|
|
|
|
Remote Sense
|
|
Outputs 1 & 2, Compensate for 0.5 V total voltage drop
|
|
|
|
|
|
|
|
|
|
|
|
General
|
|
|
Efficiency
|
|
75% typical
|
|
|
|
|
Isolation Voltage
|
|
500 VDC Input to Output, 500 VDC Output to Chassis, 500 VDC Input to Chassis
|
|
|
|
|
Material and Finish
|
|
Aluminium baseplate and safety cover
|
|
|
|
|
Input Inhibited Current
|
|
Global enable and disable function, short to negative input to inhibit
|
|
|
|
|
DC OK Signal
|
|
Optional on output voltages ≥5 VDC Isolated opto-coupler output
|
|
|
|
|
MTBF
|
|
517 kHrs to MIL-HDBK-217F at 40 ºC, GB
|
|
|
|
|
|
|
|
|
|
|
|
Environmental
|
|
|
Operating Temperature
|
|
-40 ºC to +70 ºC ambient with baseplate temperature within -40 ºC to +90 ºC
|
|
|
|
|
Extended Temperature
|
|
-55 ˚C to +90 ºC baseplate temperature, see note 4 of datasheet
|
|
|
|
|
Cooling
|
|
Baseplate-cooled. It is recommended that a thermal pad or compound is fitted between the MCC baseplate and any heatsink structure used in the system design.
|
|
|
|
|
Operating Humidity
|
|
20-95% non-condensing
|
|
|
|
|
Storage Temperature
|
|
-40 ºC to +90 ºC
|
|
|
|
|
Storage Humidity
|
|
20-95% non-condensing
|
|
|
|
|
Shock
|
|
40 g MIL-STD-810F, method 516.5-1
|
|
|
|
|
Vibration
|
|
MIL-STD-810F, method 514.5C-17 minimum integrity test for military equipment
|
|
|
|
|
|
|
|
|
|
|
|
EMC and Safety
|
|
|
Emissions
|
|
EN55022 Level B conducted MIL-STD-461E/F army ground use CE101 & CE102,DEF STAN 59-41 DCE01, DCE02
|
|
|
|
|
Conducted Immunity
|
|
MIL-STD-1275A/B/C/D, DEF STAN 61-5 Pt 6 MIL-STD-461E/F CS101, CS114, CS115, CS116,
|
|
|
|