Specifications
|
|
|
|
|
|
|
Input Voltage
|
|
90-264 VAC
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Input Current
|
|
3 A max at 90 VAC (BCC200), 6 A max at 90 VAC (BCC400)
|
|
|
|
Inrush Current
|
|
60 A at 264 VAC +25 °C cold start
|
|
|
|
Power Factor
|
|
>0.9
|
|
|
|
Earth Leakage Current
|
|
<1.5 mA at 230 VAC
|
|
|
|
Input Protection
|
|
Internal 10 A fuse
|
|
|
|
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Output Voltage Adjustment
|
|
60% to 110% Vnom
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Hold Up Time
|
|
10 ms min
|
|
|
|
Initial Set Accuracy
|
|
±1% nominal
|
|
|
|
Line Regulation
|
|
±0.5%
|
|
|
|
Load Regulation
|
|
See datasheet
|
|
|
|
Ripple and Noise
|
|
<1% pk-pk, 20 MHz bandwidth
|
|
|
|
Overvoltage Protection
|
|
105-140% Vnom (3.3 V version 130-166%)
|
|
|
|
Overload Protection
|
|
102-140% constant current limiting with auto recovery
|
|
|
|
Overtemperature Protection
|
|
Shuts down at +115 °C baseplate temperature with auto recovery
|
|
|
|
Temperature Coefficient
|
|
0.05%/°C
|
|
|
|
Remote Sense
|
|
Compensates for lead drops of up to 500 mV
|
|
|
|
Remote On/Off
|
|
A logic '0' on the Remote On/Off connection electronically disables the output.
|
|
|
|
Current Share
|
|
Up to 3 power supplies can be connected in parallel sharing within 10%, total output power derates by 10% (BCC200/400)
|
|
|
|
|
|
|
Efficiency
|
|
80% typical
|
|
|
|
Isolation
|
|
3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
|
|
|
|
Switching Frequency
|
|
PWM 360 kHz typ, PFC 90 kHz typ.
|
|
|
|
MTBF
|
|
160 kHrs to MIL-HDBK-217F at +25 °C
|
|
|
|
|
|
|
Operating Temperature
|
|
-20 °C to +70 °C with baseplate maintained below +83 °C utilizing system cooling (-40 °C option available add suffix 'L' to model number)
|
|
|
|
Storage Temperature
|
|
-40 °C to +85 °C
|
|
|
|
Cooling
|
|
Conduction via 6 mm baseplate
|
|
|
|
Operating Humidity
|
|
20-95% RH, non-condensing. Units can be conformally coated for high humidity environments add suffix 'E'
|
|
|
|
Shock & Vibration
|
|
2 g 10 min/1 cycle, 10 Hz to 500 kHz 60 mins each axis
|
|
|
|
|
|
|
Emissions
|
|
EN55022, Level B conducted and Level A radiated
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2, EN61000-3-3
|
|
|
|
ESD Immunity
|
|
EN61000-4-2, level 3 perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3, 3 V/m perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, level 3 perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4, Level 3 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5 Level 3 Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B
|
|
|
|
Safety Approvals
|
|
UL60950-1:2003, CSA 22.2 No. 60950-1-03, CE Mark LVD, EN60950-1:2001
|
|
|