AC-DC电源,DC-DC转换器,开关电源模块 - XPPower
COTS电源>>DC-DC转换器
MCC400 系列
• 400-600 Watts
• 输入抗干扰度符合MIL-STD-1275A/B/C/D 标准
• -40 ºC to +90 ºC 的工作温度
• 工厂可灵活配置1~4组输出
• 电磁兼容符合 MIL-STD-461E标准
Short Form Datasheet.pdf
459 K
 
 
Specifications
 
 
 

Input
Input Voltage
 
18-36 VDC steady state
 
 
Input Surge Rating
 
See datasheet
 
 
Input Current
 
38 A at 18 V nominal
 
 
Inrush Current
 
<60 A
 
 
Input Reverse Voltage Protection
 
Yes
 
 
Input Transient
 
MIL-STD-1275A/B/C/D
 
 
Undervoltage Lockout
 
Vin <18 VDC
 
 
Input Filter
 
MIL-STD 461E army ground use CE102, CS101, CS114, CS115 & CS116
 
 
 

Output
Output Voltage
 
O/P 1-4: Regulated outputs 2-48 VDC
 
 
Output Voltage Adjustment
 
O/P 1-4: 10-110% factory-adjustable by trim resistor. For trimming below 90% of nominal, a minimum load of 10% is required
 
 
Aux. Output Voltage
 
Vout Aux (min) = Vin -2 VDC
 
 
Aux. Output Current
 
7.14 A max
 
 
Maximum Aux Output
 
Vout clamped <36 VDC
 
 
Minimum Load
 
No minimum load (output ripple increased at Pout <10% Pout max)
 
 
Line Regulation
 
Better than 1%
 
 
Load Regulation
 
Better than 1%
 
 
Cross Regulation
 
Outputs 1-4 individually regulated
 
 
Output Set Tolerance
 
±100 mV
 
 
Hold Up
 
1 ms at 200 W output power at 28 V
 
 
External Hold Up
 
External connection for additional hold up capacitance (see datasheet)
 
 
Ripple & Noise
 
50 mV or 1% pk-pk, whichever is the greater (20 MHz bandwidth)
 
 
Low Noise (Option 'Q')
 
Outputs 1 & 2: 25 mV reduction, Outputs 3 & 4: 45 mV reduction
 
 
Temperature Coefficient
 
±0.05%/°C
 
 
Overvoltage Protection
 
110-120% of nominal output
 
 
Overcurrent Protection
 
110-120% of nominal output
 
 
Short Circuit protection
 
Continuous, with auto restart
 
 
Overtemperature Protection
 
>90 °C baseplate temperature, auto restart
 
 
Remote Sense
 
Outputs 1 & 2 +0.5 VDC
 
 
 

General
Efficiency
 
75% typical
 
 
Isolation Voltage
 
500 VDC Input to Output, Output to Chassis, Input to Chassis
 
 
Material & Finish
 
Aluminium baseplate fitted with IP20 cover
 
 
Input Inhibit
 
Global enable & disable function on Input CN1 connector TTL, Active low
 
 
Output Inhibit
 
Each regulated output has independent inhibit TTL, Active high
 
 
Inhibited Current
 
200 µA
 
 
DC OK Signal
 
Optional on output voltages >3 VDC TTL signal, Active high
 
 
 

Environmental
Operating Temperature
 
-40 °C to +70 °C ambient with baseplate temperature within -40 °C to +90 °C
 
 
Cooling
 
Baseplate-cooled. It is recommended that a thermal pad or compound is fitted between the MCC baseplate and any heatsink structure used in the system design. Consult technical sales for details
 
 
Operating Humidity
 
20-95% non-condensing
 
 
Storage Temperature
 
-40 °C to +90 °C
 
 
Storage Humidity
 
20-95% non-condensing
 
 
Shock
 
40 g MIL-STD-810F, method 516.5-1
 
 
Vibration
 
MIL-STD-810F, method 514.5C-17 minimum integrity test for military equipment
 
 
 

EMC and Safety
Emissions
 
EN55022 Level B conducted, MIL-STD-461E army ground use CE102, CS101, CS114, CS115, CS116, DEF STAN 59-41 DCE01, DCE02
 
 
Conducted Immunity
 
MIL-STD-1275A/B/C/D, DEF STAN 61-5 Pt 6
 
 
 
 
 
 
 
 
 
      Model Number
         Input
 Output
Power
 
 
 
 
 
 
 
 
MCC400
 
 
请填写您的E-mail地址,确定接受我们定期更新的产品信息!

Email地址