Specifications
|
|
|
|
|
|
|
Input Voltage
|
|
18-36 VDC steady state
|
|
|
|
Input Surge Rating
|
|
See datasheet
|
|
|
|
Input Current
|
|
38 A at 18 V nominal
|
|
|
|
Inrush Current
|
|
<60 A
|
|
|
|
Input Reverse Voltage Protection
|
|
Yes
|
|
|
|
Input Transient
|
|
MIL-STD-1275A/B/C/D
|
|
|
|
Undervoltage Lockout
|
|
Vin <18 VDC
|
|
|
|
Input Filter
|
|
MIL-STD 461E army ground use CE102, CS101, CS114, CS115 & CS116
|
|
|
|
|
|
|
Output Voltage
|
|
O/P 1-4: Regulated outputs 2-48 VDC
|
|
|
|
Output Voltage Adjustment
|
|
O/P 1-4: 10-110% factory-adjustable by trim resistor. For trimming below 90% of nominal, a minimum load of 10% is required
|
|
|
|
Aux. Output Voltage
|
|
Vout Aux (min) = Vin -2 VDC
|
|
|
|
Aux. Output Current
|
|
7.14 A max
|
|
|
|
Maximum Aux Output
|
|
Vout clamped <36 VDC
|
|
|
|
Minimum Load
|
|
No minimum load (output ripple increased at Pout <10% Pout max)
|
|
|
|
Line Regulation
|
|
Better than 1%
|
|
|
|
Load Regulation
|
|
Better than 1%
|
|
|
|
Cross Regulation
|
|
Outputs 1-4 individually regulated
|
|
|
|
Output Set Tolerance
|
|
±100 mV
|
|
|
|
Hold Up
|
|
1 ms at 200 W output power at 28 V
|
|
|
|
External Hold Up
|
|
External connection for additional hold up capacitance (see datasheet)
|
|
|
|
Ripple & Noise
|
|
50 mV or 1% pk-pk, whichever is the greater (20 MHz bandwidth)
|
|
|
|
Low Noise (Option 'Q')
|
|
Outputs 1 & 2: 25 mV reduction, Outputs 3 & 4: 45 mV reduction
|
|
|
|
Temperature Coefficient
|
|
±0.05%/°C
|
|
|
|
Overvoltage Protection
|
|
110-120% of nominal output
|
|
|
|
Overcurrent Protection
|
|
110-120% of nominal output
|
|
|
|
Short Circuit protection
|
|
Continuous, with auto restart
|
|
|
|
Overtemperature Protection
|
|
>90 °C baseplate temperature, auto restart
|
|
|
|
Remote Sense
|
|
Outputs 1 & 2 +0.5 VDC
|
|
|
|
|
|
|
Efficiency
|
|
75% typical
|
|
|
|
Isolation Voltage
|
|
500 VDC Input to Output, Output to Chassis, Input to Chassis
|
|
|
|
Material & Finish
|
|
Aluminium baseplate fitted with IP20 cover
|
|
|
|
Input Inhibit
|
|
Global enable & disable function on Input CN1 connector TTL, Active low
|
|
|
|
Output Inhibit
|
|
Each regulated output has independent inhibit TTL, Active high
|
|
|
|
Inhibited Current
|
|
200 µA
|
|
|
|
DC OK Signal
|
|
Optional on output voltages >3 VDC TTL signal, Active high
|
|
|
|
|
|
|
Operating Temperature
|
|
-40 °C to +70 °C ambient with baseplate temperature within -40 °C to +90 °C
|
|
|
|
Cooling
|
|
Baseplate-cooled. It is recommended that a thermal pad or compound is fitted between the MCC baseplate and any heatsink structure used in the system design. Consult technical sales for details
|
|
|
|
Operating Humidity
|
|
20-95% non-condensing
|
|
|
|
Storage Temperature
|
|
-40 °C to +90 °C
|
|
|
|
Storage Humidity
|
|
20-95% non-condensing
|
|
|
|
Shock
|
|
40 g MIL-STD-810F, method 516.5-1
|
|
|
|
Vibration
|
|
MIL-STD-810F, method 514.5C-17 minimum integrity test for military equipment
|
|
|
|
|
|
|
Emissions
|
|
EN55022 Level B conducted, MIL-STD-461E army ground use CE102, CS101, CS114, CS115, CS116, DEF STAN 59-41 DCE01, DCE02
|
|
|
|
Conducted Immunity
|
|
MIL-STD-1275A/B/C/D, DEF STAN 61-5 Pt 6
|
|
|