Specifications
|
|
|
|
|
|
|
Input Voltage Range
|
|
9.5-40 VDC
|
|
|
|
Input Current
|
|
See datasheet
|
|
|
|
Input Transient
|
|
MIL-STD-1275A-D, MIL-STD-704A when used in conjuction with DSF200/DSF500 filter module (see datasheet)
|
|
|
|
Undervoltage Lockout Protection
|
|
9.0-9.1 VDC
|
|
|
|
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Output Voltage Adjustment
|
|
70-110%
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Line Regulation
|
|
±0.6%
|
|
|
|
Load Regulation
|
|
±0.6%, 10-100% load
|
|
|
|
Turn-on Time
|
|
Typically 100 ms
|
|
|
|
Ripple & Noise
|
|
3%, 20 MHz BW
|
|
|
|
Overvoltage Protection
|
|
120% typical
|
|
|
|
Overcurrent Protection
|
|
108-115% (see datasheet)
|
|
|
|
Short Circuit Protection
|
|
Continuous
|
|
|
|
Overtemperature Protection
|
|
+101 °C to +107 °C case temperature
|
|
|
|
Remote Sense
|
|
Compensates for total maximum drop of 0.4 V (not fitted to 24 V output models)
|
|
|
|
Current Share
|
|
Max 4 modules, derate total output current to 90% (see datasheet)
|
|
|
|
|
|
|
Efficiency
|
|
See datasheet
|
|
|
|
Isolation Voltage
|
|
3000 VAC Input to Output, 1500 VAC Input to Case, 1500 VAC Output to Case
|
|
|
|
Switching Frequency
|
|
Typically 300 kHz
|
|
|
|
Power Density
|
|
Up to 26.7 W/Cubic Inch
|
|
|
|
Package Style
|
|
Baseplate cooled
|
|
|
|
MTBF
|
|
1 MHrs +25 °C
|
|
|
|
|
|
|
Operating Temperature
|
|
-40 °C to +85 °C
|
|
|
|
Storage Temperature
|
|
-50 °C to +125 °C
|
|
|
|
Case Temperature
|
|
+100 °C max, thermal resistance case to ambient (?CA) 5.5 °C/W
|
|
|
|
Shock
|
|
EN61373 Category 1, Class B
|
|
|
|
Vibration
|
|
EN61373 Category 1, Class B
|
|
|
|
|
|
|
Conducted Emissions
|
|
MIL-STD-461E with external components (see datasheet)
|
|
|
|
Conducted Susceptibility
|
|
MIL-STD-461E CS101, CS114, CS115, CS116 with DSF200LV filter (see datasheet)
|
|
|
|
Immunity
|
|
MIL-STD-1275A-D with DSF200LV filter (see datasheet)
|
|
|