Specifications
|
|
|
|
|
|
|
Input Voltage
|
|
85-264VAC (120-370 VDC)
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Inrush Current
|
|
2.1 A max at 115 VAC, 0.9 A max at 230 VAC
|
|
|
|
Power Factor
|
|
Complies with EN61000-3-2 for Class A equipment
|
|
|
| Earth Leakage Current |
|
120 µA max at 115 VAC, 200 µA max at 230 VAC |
|
|
| Input Protection |
|
3.15 A line & neutral fused |
|
|
|
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Output Voltage Trim
|
|
±10% output 1 via pot, outputs 2-4 track by same percentage
|
|
|
|
Initial Set Accuracy
|
|
±2% of nominal at 50% load
|
|
|
|
Minimum Load
|
|
See datasheet
|
|
|
|
Start Up Delay
|
|
<2 s
|
|
|
|
Start Up Rise Time
|
|
<100 ms
|
|
|
|
Hold Up Time
|
|
20 ms min at nominal low line & maximum power
|
|
|
|
Drift
|
|
<±0.2% after 20 mins warm up
|
|
|
|
Line Regulation
|
|
±0.5% of nominal over full input range
|
|
|
|
Load Regulation
|
|
PQ41 42 & 43: V1 & V2 ±3%, V3 & V4 ±5% of nominal. All other models: V1 ±1% V2 V3 & V4 ±5% of nominal
|
|
|
|
Transient Response
|
|
4% max deviation, recovery to within 1% in 500 µs for a 25% load change at 1 A/µs
|
|
|
|
Ripple & Noise
|
|
50 mV (Vo<=5 V); 120 mV (Vo=12, 15 V), 200 mV (Vo=24, 48 V). Measured pk-pk with a 20 MHz bandwidth
|
|
|
| Overvoltage Protection |
|
115-140% - V1 only. Cycle mains to reset |
|
|
| Overload Protection |
|
110-125%. Primary side power limiting with auto recovery. Constant current limit for single output models and foldback current limit for multi-output models. V3 & V4 PTC resetting fuses |
|
|
| Overtemperature Protection |
|
Fitted with auto restart |
|
|
| Temperature Coefficient |
|
0.02%/°C |
|
|
|
|
|
|
Efficiency
|
|
80-90% depending on model
|
|
|
|
Isolation
|
|
4000 VAC Input to Output, 1500 VAC Input to Ground, 1500 VAC Output to Ground open frame (For BF applications consult sales office), 500 VAC Output to Ground - U-channel & covered
|
|
|
|
Switching Frequency
|
|
PFC 75 kHz typical, PWM 60 kHz typical
|
|
|
|
Signals
|
|
Power fail - open collector output referenced to 0 V sense
|
|
|
| Remote Sense |
|
See datasheet |
|
|
| Remote On/Off |
|
See datasheet |
|
|
| MTBF |
|
385 kHrs at +25 °C per MIL-HDBK-217F |
|
|
|
|
|
|
Operating Temperature
|
|
-10 °C to +50 °C at full power derate to half power at 70 °C (See datasheet)
|
|
|
|
Storage Temperature
|
|
-20 °C to 85 °C
|
|
|
|
Cooling
|
|
12CFM required for full power operation
|
|
|
| Operating Humidity |
|
5% to 95% RH non-condensing |
|
|
| Operating Altitude |
|
3000 m |
|
|
| Shock |
|
30 G peak half sine 6 axis |
|
|
| Vibration |
|
2 G rms 5 Hz to 500 Hz 3 axis |
|
|
|
|
|
|
Emissions
|
|
EN55011/22 class B conducted, class A radiated
|
|
|
|
Harmonic Currents
|
|
EN61000-3-2 for Class A equipment
|
|
|
|
Voltage Flicker
|
|
EN61000-3-3
|
|
|
|
ESD Immunity
|
|
EN61000-4-2, level 3 Perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-6, 10 V rms 80% mod Perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, Level 3 Perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4, level 3 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5, level 3 Perf Criteria A
|
|
|
| Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B |
|
|
| Safety Approvals |
|
EN60601-1-1, EN60950-1:2001, UL/cUL60950:2003, CSA60601.1, UL60601-1:2003 |
|
|