Specifications
|
|
|
|
|
|
|
Input Voltage
|
|
90-264 VAC
|
|
|
|
Input Frequency
|
|
47-63 Hz
|
|
|
|
Inrush Current
|
|
20 A pk max
|
|
|
|
Power Factor
|
|
Compliant with EN61000-3-2
|
|
|
|
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Output Voltage Trim
|
|
±10% min all modules. See datasheet
|
|
|
|
Hold Up Time
|
|
20 ms min
|
|
|
|
Line Regulation
|
|
Typically 0.1%, maximum 0.3%
|
|
|
|
Load Regulation
|
|
1% max for single output modules & V1 of dual & triple output modules. 2% max for V2 & V3 of dual & triple outpt modules. A 10% load must be applied to output 1 of the high current dual module (U) & triple module (T) to achieve this figure
|
|
|
|
Ripple & Noise
|
|
50 mV or 1% pk-pk, whichever is greater, 20 MHz bandwidth
|
|
|
|
Overvoltage Protection
|
|
120-130% Vnom for single output & output 1 of high current dual modules (U) & triple modules (T)
|
|
|
|
Overload Protection
|
|
<140% of nominal rating
|
|
|
|
Short Circuit protection
|
|
Foldback
|
|
|
|
Temperature Coefficient
|
|
0.03%/°C
|
|
|
|
Remote Sense
|
|
Compensates for up to 0.5 V drop on single (S) output modules & output 1 of dual (U) & triple (T) output modules
|
|
|
|
Current Share
|
|
Single wire parallel current share. See datasheet
|
|
|
|
|
|
|
Efficiency
|
|
75% typical at nominal input
|
|
|
|
Isolation
|
|
4000 VAC Input to Output, 1500 VAC Input to Ground, 50 VAC Output to Ground
|
|
|
|
Signals & Controls
|
|
AC OK, DC OK, Global & Module Inhibit. See datasheet
|
|
|
|
MTBF
|
|
890 kHrs demonstrated
|
|
|
|
|
|
|
Operating Temperature
|
|
0 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C for fan versions. See datasheet for U-channel versions
|
|
|
|
Storage Temperature
|
|
-40 °C to +85 °C
|
|
|
|
Operating Altitude
|
|
-3000 m with no derating
|
|
|
|
|
|
|
Emissions
|
|
M3-M5: EN55011, Level A conducted with FE(x) cover, Level B conducted with ME(x) cover
|
|
|
|
ESD Immunity
|
|
EN61000-4-2, Level 3 Perf Criteria A
|
|
|
|
Radiated Immunity
|
|
EN61000-4-3, Level 3 Perf Criteria A
|
|
|
|
EFT/Burst
|
|
EN61000-4-4, Level 3 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5, Level 3 Perf Criteria A
|
|
|
|
Conducted Immunity
|
|
EN61000-4-6, Level 3 Perf Criteria A
|
|
|
|
Dips & Interruptions
|
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Criteria A, B, B
|
|
|
|
Safety Approvals
|
|
EN60601-1, CSA22.2-601, UL60601-1, CE Mark LVD
|
|
|