Specifications
|
|
|
|
|
|
|
Input Voltage Range
|
|
15.5-40.0 VDC
|
|
|
|
Input Transient
|
|
10-50 VDC for 10 s, 600 VDC for 10 µs 50 Ω source resistance per MIL-STD-704A, 100V for 50 ms 0.5 Ω source resistance per MIL-STD-1275A, ±250V for 100 µs as per MIL-STD-1275A
|
|
|
|
|
|
|
Output Voltage
|
|
Clamped <50 VDC
|
|
|
|
Output Power
|
|
50 W maximum
|
|
|
|
Inhibit
|
|
Off = TTL Low or short circuit, On = TTL High or open circuit
|
|
|
|
|
|
|
Efficiency
|
|
97% typical
|
|
|
|
Resistance
|
|
0.25 Ω input to output, <0.1 Ω case to case pin at 10 A
|
|
|
|
Power Dissipation Inhibited
|
|
0.1 W
|
|
|
|
Inrush Current
|
|
25 A at 28 Vin
|
|
|
|
Fusing
|
|
External fusing required
|
|
|
|
MTBF
|
|
846 kHrs to MIL-HDBK-217F GF at +40 °C
|
|
|
|
|
|
|
Operating Temperature
|
|
40 °C to +85 °C ambient, -40 °C to +100 °C case. Extended Temperature Range: -55 °C to +85 °C ambient, -55 °C to +100 °C case
|
|
|
|
Storage Temperature
|
|
-55 °C to +125 °C
|
|
|
|
Operating Altitude
|
|
Tested to 70000 ft (21336 m)
|
|
|
|
Operating Humidity
|
|
88% relative humidity 240h MIL-STD-810D Method 507.2
|
|
|
|
Shock
|
|
100 g MIL-STD-810D Method 516.3
|
|
|
|
Vibration
|
|
10 to 2000Hz MIL-STD-810D Method 514.3
|
|
|
|
Bump
|
|
2000 Bumps in each axes, 40 g MIL-STD-810D Method 516.3
|
|
|
|
Salt Atmosphere
|
|
48 hours MIL-STD-810E Method 509.1
|
|
|
|
|
|
|
Conducted Emissions
|
|
EN55022 Conducted Level B. MIL-STD-461E:CE101 & CE102 (EMC standards are met when used in conjuction with the MTC series)
|
|
|
|
Immunity
|
|
MIL-STD-704E. MIL-STD 704A & MIL-STD-1275A/B/C/D (EMC standards are met when used in conjuction with the MTC series)
|
|
|
|
Conducted Susceptibility
|
|
MIL-STD-461E (CS101, CS114, CS115 & CS116) - EMC standards are met when used in conjuction with the MTC series)
|
|
|