Input
|
|
|
Input Voltage Range
|
|
15.5-40.0 VDC
|
|
|
|
Transient Input Range
|
|
10 VDC maximum load for 10 s, 50 VDC for 1 s at full load
|
|
|
|
Turn On
|
|
<15.5 VDC
|
|
|
|
Turn Off
|
|
<10 VDC
|
|
|
|
Input Reverse Voltage Protection
|
|
None
|
|
|
|
Max Input Current
|
|
See datasheet
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
See datasheet
|
|
|
|
Output Voltage Trim
|
|
See datasheet
|
|
|
|
Minimum Load
|
|
No minimum load required
|
|
|
|
Line Regulation
|
|
±1% Vout nominal (15.5-40.0 Vin)
|
|
|
|
Load Regulation
|
|
±1% Vout nominal
|
|
|
|
Cross Regulation
|
|
±3% with 150 mA min load (Dual output only) - See longform datasheet
|
|
|
|
Output Set Tolerance
|
|
±100 mV or ±2% whichever is greater
|
|
|
|
Ripple & Noise
|
|
≤5 Vout: 60 mV pk-pk max, <5 Vout: 1% pk-pk, at max load & 20 MHz BW
|
|
|
|
Overvoltage Protection
|
|
110-120% Vout max (15 W & 30 W versions only)
|
|
|
|
Overcurrent Protection
|
|
105-150% at nominal input voltage
|
|
|
|
Overtemperature Protection
|
|
+102 °C to +107° C, +2 °C to +5 °C hysteresis
|
|
|
|
Remote Sense
|
|
0.5 V
|
|
|
|
Load Step Output Transient
|
|
<±3% of Vout nom (25-75% load)
|
|
|
|
Load Step Recovery
|
|
500 µs within 1% of nominal value
|
|
|
|
Line Step Output Transient
|
|
<±3% of nominal Vout (15.5-40.0 Vin)
|
|
|
|
Line Step Recovery
|
|
500 µs within 1% of nominal value
|
|
|
|
Start Up Time
|
|
<100 ms
|
|
|
|
Max Capacitive Load
|
|
300 µF x Iout max startup within 100 ms
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
See datasheet
|
|
|
|
Isolation
|
|
1500 VDC Input to Output, 1000 VDC Input to Case, 500 VDC Output to Case
|
|
|
|
Switching Frequency
|
|
Fixed 450 kHz typical
|
|
|
|
Frequency Synchronisation
|
|
400-500 kHz
|
|
|
|
Inhibit
|
|
Off = TTL Low or short circuit, On = TTL High or open circuit
|
|
|
|
MTBF
|
|
To MIL-HDBK-217F GF at +40 °C: MTC0528xx 1.7 MHrs, MTC1528xx 890 kHrs, MTC3028xx 740 kHrs
|
|
|
| |
|
|
|
|
|
Environmental
|
|
|
Case Temperature
|
|
-40 °C to +100 °C (extended range: -55 °C to +100 °C)
|
|
|
|
Operating Humidity
|
|
88% Relative Humidity 240h MIL-STD-810D Method 507.2
|
|
|
|
Storage Temperature
|
|
-50 °C to + 125 °C
|
|
|
|
Operating Altitude
|
|
Tested to 70000 Ft (21336 m)
|
|
|
|
Shock
|
|
100 g MIL-STD-810D Method 516.3
|
|
|
|
Vibration
|
|
10 to 2000 Hz MIL-STD-810D Method 514.3
|
|
|
|
Bump
|
|
2000 Bumps in each axes 40 g MIL-STD-810D Method 516.3
|
|
|
|
Salt Atmosphere
|
|
48 hours MIL-STD-810E Method 509.1
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Conducted Emissions
|
|
EN55022 Conducted Level B, MIL-STD 461E: CE102, DEF STAN 59-41: DCE01/DCE02 (MTF50 Filter Module recommended to meet these standards)
|
|
|
|
Immunity
|
|
MIL-STD-704 A, MIL-STD-704 B-F & MIL-STD-1275A/B/C/D (MTF50 Filter Module recommended to meet these standards)
|
|
|
|
Conducted Susceptibility
|
|
MIL-STD-461E CS101, CS114, CS115, CS116 (MTF50 Filter Module recommended to meet these standards)
|
|
|