Specifications
|
|
|
| |
|
|
|
Input
|
|
|
Input Voltage Range
|
|
48 VDC nominal (36 - 75 VDC). Can be configured as -48 VDC input
|
|
|
|
Input Current
|
|
9.2 A typical, 12.5 A max
|
|
|
|
Input Reverse Voltage Protection
|
|
Continuous protection with automatic recovery
|
|
|
|
Undervoltage Lockout Protection
|
|
32 - 36 VDC
|
|
|
| |
|
|
|
|
|
Output
|
|
|
Output Voltage
|
|
See Datasheet
|
|
|
|
Output Voltage Trim
|
|
±10% via potentiometer
|
|
|
|
Minimum Load
|
|
No minimum load required.
|
|
|
|
Line Regulation
|
|
±0.5% of nominal with input variation of 36-75V DC
|
|
|
|
Load Regulation
|
|
±1% of nominal with load variation 0-100%
|
|
|
|
Setpoint Accuracy
|
|
±1% of nominal with 48 VDC input and 50% load
|
|
|
|
Turn-on Time
|
|
1 s typical from application of DC input
|
|
|
|
Transient Response
|
|
<4% deviation with a 50-75-50% load change at 1 A/μs. Output returns to within 1% in less than 500 μs
|
|
|
|
Ripple & Noise
|
|
1% max pk-pk 20 MHz bandwidth, 0.1 μF capacitor connected across measurement points
|
|
|
|
Overvoltage Protection
|
|
115-140% of nominal, recycle input DC to reset
|
|
|
|
Overcurrent Protection
|
|
105-115% of max current
|
|
|
|
Short Circuit Protection
|
|
Continuous protection, trip and restart (Hiccup mode) characteristic
|
|
|
|
Temperature Coefficient
|
|
0.02%/°C (after 20 minute warm up)
|
|
|
| |
|
|
|
|
|
General
|
|
|
Efficiency
|
|
85% typical
|
|
|
|
Isolation Voltage
|
|
1500 VDC Input to Output, 1000 VDC Input to Ground, 500 VDC Output to Ground.
|
|
|
|
Switching Frequency
|
|
370 kHz typical
|
|
|
|
Power Density
|
|
11.1 W/In3
|
|
|
|
|
|
| Environmental |
|
|
Operating Temperature
|
|
-10 °C to +50 °C with full load, derate linearly to 50% load at 70 °C forced cooled.
|
|
|
|
Cooling
|
|
>20 CFM forced airflow required -H versions have integrated fan
|
|
|
|
Operating Humidity
|
|
0 to 95% RH non condensing.
|
|
|
|
Storage Temperature
|
|
-40 °C to +80 °C.
|
|
|
|
Operating Altitude
|
|
3000m.
|
|
|
|
Shock
|
|
±3 shocks in each axis (total 18 shocks) 30 g 11ms (half sine).
|
|
|
| |
|
|
|
|
|
EMC and Safety
|
|
|
Emissions
|
|
Compliant with EN61204-3 2000, EN55022 class A conducted & radiated
|
|
|
|
EFT/Burst
|
|
Compliant with EN61000-4-4 level 1 Perf Criteria A
|
|
|
|
Surge
|
|
EN61000-4-5 level 1 Perf Criteria A,
|
|
|
|
Conducted Immunity
|
|
Compliant with EN61000-4-6 level 2 Perf Criteria A
|
|
|
|
Safety Approvals
|
|
UL60950-1 (2003), CE Marked to LVD
|
|
|